- Top reward
- No cash rewards
- Top severity paid
- Not published
- Assets in scope
- 0
- Public CVEs
- 6
- Last change
- No changes yet
At a glance
What to know before you start testing.
- No cash rewards
- A disclosure program: you report for credit, not money.
- Report by email
- [email protected]
- No safe harbor
- No promise about legal action.
Rewards
What the company's own policy page says it pays.
The policy link is dead. The page answered "not found" when we checked on 12 Nov 2026, and the company's security.txt does not point to a new one. The program may have moved or closed; confirm on the company's site before you test.
This program does not pay cash rewards.
Scope
0 assets you may test.
Self-hosted does not list the scope of this program publicly. Check its policy.
Changes
Tracked since 11 Nov 2026. Last checked 5 hours ago.
No changes yet. When the rewards or scope move, you will see it here and in the RSS feed.
Public CVEs
Published vulnerabilities in this vendor's products, from the NVD.
| CVE | Summary | Severity | Published |
|---|---|---|---|
| CVE-2023-47262 | The startup process and device configurations of the Abbott ID NOW device, before v7.1, can be interrupted and/or modified via physical access to an internal serial port. Direct physical access is required to exploit. | Medium 5.2 | 14 Nov 2023 |
| CVE-2020-8997 | Older generation Abbott FreeStyle Libre sensors allow remote attackers within close proximity to enable write access to memory via a specific NFC unlock command. NOTE: The vulnerability is not present in the FreeStyle Libre 14-day in the U.S (announced in August 2018) and FreeStyle Libre 2 outside the U.S (announced in October 2018). | High 8.8 | 16 Feb 2020 |
| CVE-2017-12712 | The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmwa | High 8.8 | 25 Apr 2018 |
| CVE-2017-12714 | Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitiga | Medium 6.5 | 25 Apr 2018 |
| CVE-2017-12716 | Abbott Laboratories Accent and Anthem pacemakers manufactured prior to Aug 28, 2017 transmit unencrypted patient information via RF communications to programmers and home monitoring units. Additionally, the Accent and Anthem pacemakers store the optional patient information without encryption. CVSS v3 base score: 3.1, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N. Abbott has developed a | Medium 6.5 | 25 Apr 2018 |
| CVE-2017-5149 | An issue was discovered in St. Jude Medical Merlin@home, versions prior to Version 8.2.2 (RF models: EX1150; Inductive models: EX1100; and Inductive models: EX1100 with MerlinOnDemand capability). The identities of the endpoints for the communication channel between the transmitter and St. Jude Medical's web site, Merlin.net, are not verified. This may allow a man-in-the-middle attacker to access | High 8.9 | 13 Feb 2017 |