- Top reward
- No cash rewards
- Top severity paid
- Not published
- Assets in scope
- 2
- Public CVEs
- 27
- Last change
- No changes yet
At a glance
What to know before you start testing.
- No cash rewards
- A disclosure program: you report for credit, not money.
- Report by email
- [email protected]
- Publish after a fix
- Coordinate the timing with the company.
Rewards
What the company's own policy page says it pays.
This program does not pay cash rewards.
- Hall of fame
-
Yes
The following independent security researchers are recognized for their valuable contributions to the security of Baxter's products.
Summarised with AI from the company's policy, read 12 Nov 2026, and checked word for word against it. Read the original
Scope
2 assets you may test, 2 excluded.
Domains 1
- baxter.com
Products and areas 1
- Baxter’s commercially available products
Out of scope (2)
- devices in use
- software that is in a production environment
Rules
What the policy asks of you, and the bug types it won't reward, quoted from Hillrom's policy.
While testing
-
Adhere to all applicable laws and regulations;
-
Do not conduct any testing that requires social engineering or phishing attacks;
-
Do not interfere, disrupt or otherwise impair the ordinary operation of any device, service, or the environment in which it runs.
-
Do not conduct any testing that could harm patients or interrupt care, or downgrade of in-use safety functions.
-
Do not conduct any testing that could manipulate clinical performance and/or data
-
Do not conduct any testing that accesses, modifies, or copies personal data
-
Do not test devices in use or software that is in a production environment
-
Do not take actions to exploit any vulnerability
-
Do not take actions that could make changes to a product or system after the test is completed
Not accepted
-
technical support information on Baxter products
-
Adverse Events
-
Product Quality Complaints
Summarised with AI from the company's policy, read 12 Nov 2026, and checked word for word against it. Read the original
Changes
Tracked since 11 Nov 2026. Last checked 6 hours ago.
No changes yet. When the rewards or scope move, you will see it here and in the RSS feed.
Public CVEs
Published vulnerabilities in this vendor's products, from the NVD.
| CVE | Summary | Severity | Published |
|---|---|---|---|
| CVE-2024-6795 | In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal's database. An attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content and/or perform administrative operations including shutt | Critical 10.0 | 9 Sep 2024 |
| CVE-2024-6796 | In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal's database and/or modify content. | High 8.2 | 9 Sep 2024 |
| CVE-2022-26394 | The Baxter Spectrum WBM does not perform mutual authentication with the gateway server host. This may allow an attacker to perform a man in the middle attack that modifies parameters making the network connection fail. | Medium 5.5 | 9 Sep 2022 |
| CVE-2022-26392 | The Baxter Spectrum WBM (v16, v16D38) and Baxter Spectrum WBM (v17, v17D19, v20D29 to v20D32) when in superuser mode is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensitive information. | Low 3.1 | 9 Sep 2022 |
| CVE-2022-26393 | The Baxter Spectrum WBM is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensitive information or cause a Denial of Service (DoS) on the WBM. | Medium 5.0 | 9 Sep 2022 |
| CVE-2022-26390 | The Baxter Spectrum Wireless Battery Module (WBM) stores network credentials and PHI (only applicable to Spectrum IQ pumps using auto programming) in unencrypted form. An attacker with physical access to a device that hasn't had all data and settings erased may be able to extract sensitive information. | Medium 4.2 | 9 Sep 2022 |
| CVE-2021-43935 | The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accept manual entry of any active directory (AD) account provisioned in the application without supplying a password, resulting in access to the application as the supplied AD account, with all associated privileges. | High 8.1 | 15 Dec 2021 |
| CVE-2020-12037 | Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device. | High 7.5 | 29 Jun 2020 |
| CVE-2020-12039 | Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed. | Low 2.4 | 29 Jun 2020 |
| CVE-2020-12040 | Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the | Critical 9.8 | 29 Jun 2020 |
| CVE-2020-12041 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary configuration changes to network settings of the WBM, and allows the WBM to be rebooted. Temporary configuration changes to network settings are removed upon reboot. | Critical 9.4 | 29 Jun 2020 |
| CVE-2020-12043 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted. | Critical 9.8 | 29 Jun 2020 |
| CVE-2020-12045 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials. | Critical 9.8 | 29 Jun 2020 |
| CVE-2020-12047 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials. | Critical 9.8 | 29 Jun 2020 |
| CVE-2020-12048 | Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Pho | High 7.5 | 29 Jun 2020 |
| CVE-2020-12008 | Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI. | High 7.5 | 29 Jun 2020 |
| CVE-2020-12012 | Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials for the ExactaMix application. Successful exploitation of this vulnerability may allow an attacker with | Medium 6.1 | 29 Jun 2020 |
| CVE-2020-12016 | Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an atta | Critical 9.8 | 29 Jun 2020 |
| CVE-2020-12020 | Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13 and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 does not restrict non administrative users from gaining access to the operating system and editing the application startup script. Successful exploitation of this vulnerability may allow an attacker to alter the startup script as the limited-access user. | Medium 6.1 | 29 Jun 2020 |
| CVE-2020-12024 | Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from an unauthorized user with physical access. Successful exploitation of this vulnerability may allow an attacker with physical access to the system the ability to load an unauthorized payload or unauthorized access to the hard drive by bootin | Medium 6.1 | 29 Jun 2020 |
| CVE-2020-12032 | Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencrypted database. This could allow an attacker with network access to view or modify sensitive data including PHI. | Critical 9.1 | 29 Jun 2020 |
| CVE-2020-12035 | Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings and calibration. | Medium 4.9 | 29 Jun 2020 |
| CVE-2020-12036 | Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device. | High 7.5 | 29 Jun 2020 |
| CVE-2014-5431 | Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make un | Medium 6.8 | 26 Mar 2019 |
| CVE-2014-5432 | Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to feat | Critical 9.8 | 26 Mar 2019 |
| CVE-2014-5433 | An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, whic | Critical 9.8 | 26 Mar 2019 |
| CVE-2014-5434 | Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software c | Critical 9.8 | 26 Mar 2019 |